Overvoltage arresters
Provide safety in case of overvoltage, i.e. short-timed high-tension peaks. It cut down the overvoltage to safety level. Overvoltage is caused by an atmospheric discharge e.g. a lightning shot into the outside air conduction, or into the lightning road system, starting of an equipment with high induction, turn off of the circuit breakers or high rated fuses, using of semiconducted switches, thyristor switch or starting of the electromotors. Overvoltage arresters are in class B, C, D, (Type 1, 2, 3) connected to cascades. At the biggining of whole system is an overvoltage arrester damping the higher overvoltage and brings it down to the level suitable for the next class of overvoltage arrester, untill the outgoing voltage from the last arrester is suitable for an appliance.
We offer overvoltage arresters NADER. Marking NDM1G - overvoltage arresters and NDM1Q - undervoltage arresters. They can be used only with the breakers NDM1 Nader.
This is the specification of this overvoltage arresters: overvoltage arresters
We offer also overvolgage arrestiers of this types:
SJB Lightning current arresters - stage 1 - type 1
Maximum constant operating voltage AC 260 ÷ 440 V a.c.
Lightning current (10/350) - peak value 35 ÷ 100 kA
Rated discharge current (8/20) 35 ÷ 100 kA
Rated frequency min. 50 Hz
Rated frequency max. 60 Hz
Voltage protection level <1,5 kV / < 4 kV
Maximum backup fuse 125 A / 250 A
Arrester classification according to EN 61643-11 T1
Degree of protection IP20
Conductor rigid max. 35 mm2 / 50 mm2
Ambient temperature min. -40 °C
Ambient temperature max. 85 °C
EN 61643-11
IEC 61643-1
VDE 0675-6
| Iimp [kA] | Version | Type | Number of modules |
| (10/350) μs | |||
| 35 | Encapsulated arrester gap | SJBpro35 | 1 |
| Encapsulated arrester gap with electronic ignition realise | SJBpro35/1,5 | 1 | |
| 50 | Arrester gap | SJBplus50 | 2 |
| Arrester gap with electronic ignition realise | SJBplus50/1,5 | 2 | |
| 100 | Summary arrester gap with electronic ignition realise | SJB100/NPE/1,5 | 2 |
SJBpro35 is used in home applications, SJBplus50 is assigned for industrial applications.
Voltage protection level for SJBpro35/1,5 is Up = 1,5 kV and for SJBpro35/1,5 is Up = 1,5 kV.
By using SJBpro35and SJBplus50 is needed to observe the length of the line between type1 and type2 min. 10 m.
SVL, SJL Surge voltage arresters - stage 2 - type 2
Maximum constant operating voltage AC 275 V a.c.
Maximum constant operating voltage DC 350 V d.c.
Rated discharge current (8/20) 10 ÷ 16 kA
Maximum discharge current (8/20) 20 ÷ 40 kA
Rated frequency 50 Hz
Voltage protection level < 1,35 kV
Maximum backup fuse 100 A
Arrester classification according to EN 61643-11 T2
Degree of protection IP20
Conductor rigid max. 16 mm2
Ambient temperature min. -25 °C
Ambient temperature max. 45 °C
EN 61643-11
IEC 61643-1
VDE 0675-6
|
Version
|
Type
|
Number of modules
|
|
Varistor
|
SVL275
|
1
|
|
Varistor+signalling
|
SVL275S
|
1
|
|
Varistor+arrester gap
|
SJL275
|
1
|
|
Varistor+ arrester gap + signalling
|
SJL275S
|
1
|
SVM Surge voltage arresters with removable module - stage 2 - type 2
Maximum constant operating voltage AC 260 ÷ 440 V a.c.
Maximum constant operating voltage DC 350 ÷ 585 V a.c.
Rated discharge current (8/20) 20 kA
Maximum discharge current (8/20) 40 kA
Rated frequency 50 Hz
Voltage protection level < 2.2 kV
Maximum backup fuse 125 A
Arrester classification according to EN 61643-11 T2
Degree of protection IP20
Conductor rigid max. 35 mm2
Ambient temperature min. -40 °C
Ambient temperature max. 80 °C
EN 61643-11
IEC 61643-1
VDE 0675-6
|
Desing
|
Uc[V]
|
Description
|
Type
|
Number of modules
|
|
Varistor
|
275
|
Base+replaceable module
|
SVM275-Z
|
1
|
|
|
|
Base with signalling contact, replaceable module
|
SVM275-ZS
|
1
|
|
|
|
Replaceable module
|
SVM275
|
1
|
|
|
440
|
Base+replaceable module
|
SVM440-Z
|
1
|
|
|
|
Base with signalling contact, replaceable module
|
SVM440-ZS
|
1
|
|
|
|
Replaceable module
|
SVM440
|
1
|
|
Discharge
arrester
|
260
|
Base+replaceable module
|
SVM260/NPE-Z
|
1
|
|
|
|
Replaceable module
|
SVM260/NPE
|
1
|
In the case of a failure it is sufficietn to change the module without the need of turning the device off.
SVD Surge voltage arresters - stage 3 - type 3
Maximum constant operating voltage AC 253 V a.c.
Rated loading current / 40 °C 20 A
Rated discharge current (8/20) < 1,5 kA / < 3 kA
Maximum discharge current (8/20) < 5 kA / < 10 kA
Off-load voltage 6 kV
Rated frequency 50 Hz
Voltage protection level between L-PE, N-PE < 1,5 kV
Maximum backup circuit breaker 16 A / 20 A
Maximum backup fuse 16 A / 20 A
Arrester classification according to EN 61643-11 T3
Degree of protection IP20
Conductor rigid max. 4 mm2
Ambient temperature min. -40 °C
Ambient temperature max. 85 °C
EN 61643-11
IEC 61643-1
VDE 0675-6
|
Design
|
Description
|
Type
|
Number of modules
|
|
On DIN rail
|
SET (base + replaceble module)
|
SVD250M-ZS
|
1
|
|
|
Replaceble module
|
SVD250M
|
1
|
|
On wiring boxes
|
SET (base + replaceble module)
|
SVD250-ZS
|
|
|
|
Replaceble module
|
SVD250
|
|